MIL-PRF-15733/58C
FIGURE 2. Voltage conditioning test circuit.
VERIFICATION:
Qualification Inspection: Requirements of this specification sheet not currently required in MIL-PRF-15733 shall
be included in qualification inspection as group VI (see table II).
TABLE II. Qualification inspection. 1/
Inspection
Number of samples
Number of
to be inspected
defectives allowed
Group VI
Transient voltage
4
0
Inrush transients
4
1/ This table is an addition to table III of MIL-PRF-15733.
Conformance inspection: Conformance inspection shall be as specified in MIL-PRF-15733 except group A
inspection shall be as specified in table III of this specification sheet, in the order shown. Lots that have greater
than 5 percent rejects shall be considered reject lots. Reject lots may, at the option of the manufacturer, be
resubmitted to 100 percent group A inspection; however, resubmitted lots which have greater than 2 percent
rejects shall be rejected and may not be resubmitted for reinspection.
Group C inspection shall be as specified in MIL-PRF-15733 and shall include the tests specified in table IV of this
specification sheet.