MIL-STD-1285D
w/ CHANGE 1
APPENDIX H
FSC 5945 - RELAYS
H.1 SCOPE
H.1.1 Scope. The following define the requirements that pertain to both commercial and military electronic devices. Where the requirements are not stated, refer to sections 4 and 5 herein. This appendix is a mandatory part of this standard. The information contained herein is intended for compliance.
This appendix establishes the marking requirements that apply to a specific FSC. These requirements are to be applied in addition to the requirements of sections 4 and 5 herein. In the event of conflict between this appendix and section 4 or 5, the appendix shall take precedence.
H.2 APPLICABLE DOCUMENTS. This section is not applicable to this appendix. H.3 GENERAL REQUIREMENTS
H.3.1 Functional marking.
H.3.1.1 Terminals. Terminals shall be marked in accordance with figure H-1. The contact arrangements and symbols are for reference only, and unless otherwise specified in the acquisition document, shall not be marked on the relay. Marking the terminal identification shall be on the circuit diagram only.
FIGURE H-1. Symbols and markings for terminals.