MIL-PRF-28861D
4.6.2 Thermal shock and voltage conditioning (see 3.7). Filters shall be subjected to the tests of 4.6.2.1 and
4.6.2.2.
4.6.2.1 Thermal shock. Filters shall be tested as specified in method 107 of MIL-STD-202. The following details
and exceptions shall apply:
a. Test condition A, except that in step 3, sample units shall be tested at +125°C.
b. Mounting (class S filters only). Filters shall be mounted in a through-hole and torqued in place on a rigid
metal plate to the specified value (see 3.1). (Note: Not applicable to solder-in types).
c. Measurements during the test (class S filters only). At completion of or during the final cycle and before the
filter is removed from the plate, measure and record insulation resistance at +125°C.
4.6.2.2 Voltage conditioning.
4.6.2.2.1 Class B filters. Filters shall be tested as specified in method 108 of MIL-STD-202. The following details
and exceptions shall apply:
a. Test temperature and tolerance: +125°C ± 3°C.
b. Operating conditions:
DC rated filter: 2 x rated voltage for 164 ± 4 hours.
(1)
(2)
For filters with ac and dc ratings, or ac ratings only: Apply 1.2 x rated ac voltage at maximum rated
frequency for 164 ± 4 hours.
c. Mounting: Filters shall be mounted in such a way that the specified voltage may be applied between the
terminals and case.
d. Measurements after test: Insulation resistance shall be measured as specified in 4.6.13.2.
4.6.2.2.2 Class S filters. Filters shall be tested as specified in method 108 of MIL-STD-202. The following details
and exceptions shall apply:
a. Test temperature and tolerance: +125°C ± 3°C.
b. Operating conditions.
(1) DC rated filter: 2 x rated voltage.
(2) Filters with ac and dc ratings, or ac ratings only: 1.2 x rated ac voltage at maximum rated frequency.
(3) Polarity of voltage: The polarity of the voltage shall be positive on the case during the first 24 to 72
hours and then reversed to negative on the case for the remaining portion of the test.
c. Mounting: Filters shall be mounted in such a way that the specified voltage may be applied between the
terminals and case. The method of electrically contacting the case and one terminal of the filter must be
adequate to ensure that all the filters will be properly conditioned.
d. Test circuit: The test circuit shall be equivalent to that shown on figure 1. The maximum series resistance
with each filter shall be 5.00 ohms. The fuse shall have a maximum rating of 0.25 ampere. The power
supply shall be capable of supplying five times the maximum current rating of the fuse.