MIL-PRF-28861D
3.8 Dielectric withstanding voltage. When filters are tested as specified in 4.6.3, there shall be no breakdown,
flashover, or impairment of any characteristics sufficient to cause failure of the filter.
3.9 Capacitance to ground and dissipation factor. When filters are tested as specified in 4.6.4, the capacitance to
ground and dissipation factor shall be as specified (see 3.1).
3.10 Insertion loss. When filters are tested as specified in 4.6.5, the insertion loss shall be as specified (see 3.1).
3.11 Voltage drop. When filters are tested as specified in 4.6.6, the voltage drop shall be as specified (see 3.1).
3.12 DC resistance. When filters are tested as specified in 4.6.7, the dc resistance shall be as specified (see 3.1).
3.13 Radiographic inspection. When filters are tested as specified in 4.6.8, radiographic examination shall not
disclose evidence of any defects listed in 4.6.8.
3.14 Seal (hermetically sealed filters only). When filters are tested as specified in 4.6.9, for the fine leak test, the
leakage rate shall not exceed the maximum leakage rate as specified (see 3.1). When filters are tested as specified
in 4.6.9, for the gross leak test, there shall be no continuous stream of bubbles emanating from the filter, nor shall
there be any evidence of leakage of compound from the body of the filter.
3.15 Voltage and temperature limits of capacitance. When filters are tested as specified in 4.6.10, the change in
capacitance shall not exceed the value specified (see 3.1).
3.16 Temperature rise. When filters are tested as specified in 4.6.11, the maximum temperature rise shall be as
specified (see 3.1).
3.17 Barometric pressure (reduced). When filters are tested as specified in 4.6.12, there shall be no breakdown,
flashover, or impairments of any characteristics sufficient to cause failure of the filter.
3.18 Insulation resistance. When filters are tested as specified in 4.6.13, the insulation resistance shall not be
less than specified (see 3.1).
3.19 Current overload. When filters are tested as specified in 4.6.14, there shall be no evidence of physical
damage. After the test, filters shall meet the following requirements:
Insulation resistance (+25°C): Shall meet initial requirements (see 3.1).
Voltage drop: Shall meet initial requirements (see 3.1).
3.20 Resistance to solvents. When filters are tested as specified in 4.6.15, there shall be no evidence of physical
damage and the marking shall remain legible.
3.21 Vibration (high frequency). When filters are tested as specified in 4.6.16, there shall be no intermittent, open
or short-circuiting, and no physical damage to the filter. After the test, in Group B inspection, Class B filters shall
meet the following requirement:
Insertion loss (+25°C): Shall meet initial requirements (see 3.1).
3.22 Random vibration. When filters are tested as specified in 4.6.17, there shall be no intermittent open or short-
circuiting, and there shall be no evidence of physical damage to the filter. After the test, filters shall meet the
following requirement:
Insertion loss (+25°C): Shall meet initial requirements (see 3.1).
7