MIL-PRF-28861D
d. Test during vibration to determine intermittent open or short-circuiting.
e. Examination after test: Filters shall be inspected for evidence of physical damage.
f. Measurements after test (Group B inspection only): Class B filters shall be subjected to the insertion-loss
test (see 4.6.5).
4.6.17 Random vibration (see 3.22). Filters shall be tested in accordance with method 214 of MIL-STD-202. The
following details and exceptions shall apply:
a. Mounting of specimens: Filters shall be rigidly mounted by the body.
b. Electrical load: DC rated voltage and current shall be applied continuously during vibration.
c. Test condition: (I-C for class B; I-F for class S.) The test shall be conducted for 1½ hours in each of three
mutually perpendicular directions.
d. During vibration filters shall be monitored to determine intermittent open and short-circuiting. Detecting
equipment shall be sufficiently sensitive to detect any interruption of 0.5 ms or greater duration.
e. Examination after test: Filters shall be inspected for evidence of physical damage.
f. Measurements after test: Filters shall be subjected to the insertion-loss test (see 4.6.5).
4.6.18 Thermal shock and immersion (hermetically sealed filters only) (see 3.23).
4.6.18.1 Thermal shock. Filters shall be tested in accordance with method 107 of MIL-STD-202. The following
details and exceptions shall apply:
a. Test condition.
(1) Class B: Test condition A, except step 3 temperature shall be +125°C +3°C, -0°C.
(2) Class S: Test condition A-1, except step 3 temperature shall be +125°C +3°C, -0°C.
b. Measurements before and after cycling: Not applicable.
4.6.18.2 Immersion. Following thermal shock, filters shall be tested in accordance with method 104 of
MIL-STD-202. The following details shall apply:
a. Test condition A.
b. Measurements after final cycle: Dielectric withstanding voltage with 90 percent of the voltage specified in
4.6.3 applied for 5 ± 1 second, insulation resistance (at +25°C), and insertion loss as specified in 4.6.13
and 4.6.5, respectively.
c. Visual inspection: After the test, filters shall be visually inspected for corrosion and obliteration of marking.
4.6.19 Resistance to soldering heat (see 3.24). Filters shall be tested in accordance with method 210 of MIL-
STD-202, the following details shall apply:
a. Depth of immersion in the molten solder shall be to a point 0.0625 ± 0.031 inch (1.59 ± 0.79 mm) from the
case.
b. Test condition letter B.
30