MIL-PRF-15733J
TABLE X. Current rating.
Symbol
Rated
Symbol
Rated
current
current
Amperes
Amperes
A
0.1
H
15.0
B
0.3
J
20.0
C
0.5
L
30.0
D
1.0
N
55.0
X
1.5
P
70.0
Y
2.0
R
100.0
E
3.0
S
150.0
F
5.0
T
200.0
Z
7.0
U
300.0
G
10.0
V
500.0
W
As specified
6.7.1.3 Insertion-loss characteristic. The insertion-loss characteristic is identified by a single letter; in accordance
with table XI.
TABLE XI. Minimum insertion loss under full load.
Frequency in megahertz shown as column head and insertion loss shown in column 1/
Symbol
0.15
0.3
0.6
1
10
20
40
100
500
1,000
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
A
85
85
85
80
60
60
60
45
20
20
B
40
50
60
60
60
60
60
60
60
60
C
50
60
60
60
60
60
60
---
---
---
D
50
60
60
60
60
60
60
60
60
60
E
30
45
60
75
55
50
45
30
20
---
F
40
40
40
40
40
40
40
---
---
---
G
45
60
80
80
80
80
75
70
70
70
H
50
50
60
60
60
60
60
60
50
50
J
60
70
80
80
80
80
80
80
80
80
K
40
50
60
60
60
60
60
60
60
60
L
70
70
70
70
60
60
60
60
60
60
M
50
70
80
80
75
70
65
60
55
50
W
As specified 2/
1/ Full load insertion loss measurements shall be made from .15 to 20 MHz. Above 20 MHz, insertion
loss measurements shall be made under no-load.
2/ W may also be used to indicate minimum insertion loss under no load .
21
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business