MIL-PRF-28861D
c. Cooling time prior to final examinations and measurements: Sufficient time shall be allowed for the filters to
stabilize at room ambient temperature. Filters shall then be examined for evidence of physical damage and
Insertion loss (25°C) and insulation resistance (25°C) shall be measured in accordance with 4.6.5 and
4.6.13 respectively.
4.6.20 Salt atmosphere (corrosion) (see 3.25). Filters shall be tested in accordance with method 101 of
MIL-STD-202. The following details and exceptions shall apply:
a. Test condition A (96 hours).
b. Visual inspection: After completion of the test, filters shall be visually inspected for corrosion and
obliteration of marking.
4.6.21 Destructive physical analysis (see 3.26). Filters shall be inspected in accordance with appendix B of this
specification.
MIL-STD-202. The following details and exceptions shall apply:
a. Mounting: Securely fastened by normal mounting means; when applicable, leads and connecting wires
must be supported to prevent damage to the filter.
b. Test condition.
(1) Class B filters: Test condition I (100 g's).
(2) Class S filters: Test condition F (1,500 g's).
c. Electrical load during shock: During the test, a potential of 100 percent of dc rated voltage shall be applied
between the terminals and case.
d. Measurements during test: Monitor for intermittent open- or short-circuiting.
e. Measurements after the test (Qualification inspection only): Filters shall be subjected to the insertion-loss
test (see 4.6.5).
4.6.23 Terminal strength (see 3.28). Filters shall be tested in accordance with method 211 of MIL-STD-202. The
following details and exceptions shall apply:
a. Test condition A (pull test).
b. Applied force: 5 pounds.
c. Inspection after test: Filters shall be visually inspected for evidence of loosening or rupturing of the terminals.
4.6.24 Moisture resistance (hermetically sealed filters only) (see 3.29). Filters shall be tested in accordance with
method 107 of MIL-STD-202, test condition A (except at step 3 temperature shall be +125°C +3°C, -0°C) and no
measurements shall be made before and after cycling. Filters shall then be tested in accordance with method 106 of
MIL-STD-202. The following details and exceptions shall apply:
a. Mounting: Securely fastened by normal mounting means.
b. Initial measurements: Not applicable.
c. Polarization voltage: During steps 1 to 6, inclusive, a dc potential of 100 volts or rated voltage, whichever
is less shall be applied between the terminals and case. The potential applied to the terminals shall be
positive with respect to the case.